PROJECT
Product descriptions
TE-2000 TE-2100 TE-2200 Sensor

TE-2100

Always the best spot, through continuous product development
, we hope to keep.

TE-2100

Model Name
TE-2100
Detail information
Rated Voltage(Input) : 1-Phase AC 220 V
Max Output Volatage : 3-Phase AC 220V
Air curtain control function(A2,A0)
Application of inverter-only microprocessor
Control value setting and operation status checking by applying LCD module
Positioning: Limit Switch, Rotary Encoder
Exterior box painting: fire preparation, rust-proof spray painting
I/O : UP,DOWN,STOP,ONE,HALF,24V,SS,LS,IT-IN,IT-O,EMG,BK1,BK2,ARM1,ARM2
Application of Control : High Speed Automatic Door, Other 3 Phase AC Motor
※ Model-specific features may be changed.
Category Specification
~ 1HP ~ 2HP
Rated Output Motor Capacity ~0.75KW ~1.5KW
Rated Output ~ 0.75KVA ~ 1.5KVA
Rated Output Current 5A 7A
Rated Output Valtage AC 3-Phase 220V
Power Voltage/Frequency 1-Phase AC 200~ 230V,50/60㎐
Allowable voltage variation 입력전압기준 ± 10% 이내
Allowable frequency variation 입력 주파수 기준 ± 5% 이내
Control Control Method V/F Control
Carrier Frequency 10 KHz
Frequency setting range 10.0 ~ 80㎐
Braking Dynamic braking(if necessary)
Operatione MODE Automatic / Manual
Protective function Over Current Trip at more than 170% of rated current
Over Load Power stop if rated current is maintained for 2 seconds or more than 150% of the current
Over Voltage Trip if over 140% of DC Link
Under Voltage Trip if under 50% of DC Link
Over Temperature Trip at 85 to 95 [°C] or higher
Positioning Sensor If ENCODER Sensor input is not present for 1 second, output stop /
LIMIT Sensor input is not present for 10 seconds, output stop
Setting function Maximum output frequency 30 ~ 80㎐, Default : 60㎐
Accelation Time 0.4 ~ 2sec, Default : 0.8sec
Decelation Time 0.2 ~ 2sec, Default : 0.4sec
Stop Frequency 10~30 Hz
Rated Voltage V/F 50~100%
INTERLOCK Selection ON/OFF
Wait time to Open end 1~250sec, Default : 5sec